Florian Schmidt a08e9f781f Analysis: read a rarely-read meter as coarse, not absent; newest rows first
ci / build-test (push) Successful in 2m41s
Three things a reported Heizoel page got wrong at once. Its tank is dipped
a few times a year and its burner read every few months, which is exactly
the shape the coverage rules had not been walked through.

"No data" for data that exists. A tank books nothing until the next
dipstick closes the interval, so the stretch after the last dipstick is
covered by no run at all, and a bucket no run covers was reported missing.
The burner, whose run reaches into the window, said "only coarser data" --
the honest answer -- so one card claimed there was nothing while the
coverage panel beside it listed years of data. A bucket that no run covers,
no gap overlaps and no opening balance explains now reports the meter's
resolution when its preceding coverage is within one interval of its own
class: it is not silent, it is read rarely. A meter that does book its own
buckets and stops -- a dead hourly source, a sheet asked about a later
month -- still reads missing.

Auto answering twelve months with one bar. Coarse only means "longer than
a month", so a dipstick taken each autumn straddles a New Year as surely
as a month start: coarsening the chart to years bought nothing and cost
every point. The planning resolution now caps coarse at month when a run
crosses a local year edge, and a series that cannot resolve the natural
size no longer coarsens the whole chart -- it is drawn at that size with
its buckets marked, which the chart and table already explain.

A page contradicting itself. The comparison line above the ranking was fed
the leading measure's matched coverage but worded as if it spoke for the
page, directly above a burner row that did compare. It now names the figure
it is about.

Alongside: the "largest changes" ranking no longer drops a meter whose
change is not comparable. It ranks what can be ranked, then lists the rest
with their values and the reason -- the tank had been vanishing from its
own energy type. And every dated table now reads newest first, as lists
are read; charts stay chronological left to right, and the CSV export
stays ascending for spreadsheets.

A-41 to A-43 in the note record the three rules.
2026-09-20 12:44:32 +02:00
Florian Schmidt 8940ef25c3 Analysis: one selected period, one set of numbers, on every page
ci / build-test (push) Successful in 2m31s
The dashboards told several stories at once. Overview asked for full
calendar years, meter detail for a fixed 12-month window that was really
13, Trends for 24 months with an Apply button, and the energy pages for
60. Each page derived "today" from UTC, so the first hours of a local day
belonged to yesterday. A missing tariff, a month nobody measured and a
genuine zero all rendered as 0. And a virtual meter -- the one thing the
spreadsheet leans on hardest -- was excluded from analysis outright:
MeterPeriodService returned null for it and the page offered a flow
diagram instead.

docs/DASHBOARD_ANALYSIS_CHANGE_BRIEF.md is the work order. Every choice it
left open is settled in docs/ANALYSIS_IMPLEMENTATION_NOTE.md as D-01..D-58
plus amendments A-01..A-30; code, tests and release notes cite those ids.

The analysis layer

Core/Analysis holds the pure rules: period presets resolved once in the
instance zone into a local date range and a half-open UTC range, bucket
plans, calendar-unit comparisons, coverage runs with a resolution class,
normalized quantities and units, the totals policy, the virtual formula
parser/validator/evaluator, and the cost calculator. "Now" comes from
TimeProvider; services never read the clock.

Normalization now writes, in the same transaction as consumption and by
diff, per-meter rollups by local day and month plus coverage runs and a
rollup state (AnalysisDataWriter). AnalysisReader answers a request from
those tables -- month rollups for month and year buckets, day rollups
otherwise, at most two partial edge days from consumption -- and
CostReader prices the result month by month. Pages, /api/v1 and the CSV
export read nothing else. The unused continuous aggregates are dropped.

The reader's statement count per request is constant whether it covers one
meter or a thousand. On a synthetic 1,000-meter, ten-year instance the
brief's target request (100 meters, ten years, monthly) takes 374 ms
against a two-second target, and the Overview went from 48,244 SQL
statements per load to 205.

Missing is not zero

Every bucket carries a status -- available, partial, missing, unresolved,
invalid, pending -- derived from coverage, never from the amount, with
provenance and a reason code beside it. A true zero is a number and a bar
on the baseline; an unknown bucket is a gap that says why; a month whose
data only exists monthly says so instead of inventing daily detail; a
scope with no tariff says "not priced" instead of 0. Rows whose interval
closes after now are reported separately rather than counted.

Virtual meters are analysis subjects

A virtual meter stores a canonical definition -- expression over m<id>
references, result kind, unit and cost rule -- validated on save and on
read for syntax, unknown or self references, loops and unit/kind rules.
It is evaluated on read from its sources' rollups over their joint
coverage: a missing source makes the bucket missing, an observed zero is
a valid input, a non-finite result is invalid with its dependency path,
and the page lists each source's contribution. Topology links are
topology only and never rewrite a saved calculation; expression-less
meters from older installs are converted once at startup. The editor has
Sum, Difference and Advanced modes with a live preview.

Totals and the bill

Per energy type the totals policy separates use, grid import, export,
generation and runtime, marks breakdown meters as breakdowns and virtual
meters as views, and never adds across units. The bill follows it: grid
import where there is one, separately priced subsections at their own
price, feed-in only on export meters, standing charges once per scope per
local day, manual costs once on their start day, categories as
non-overlapping covers whose composition reconciles to the bill. The
seeded demo's yearly totals now match the spreadsheet.

Pages and navigation

The period lives in the URL and every page reads the same contract, so a
link, a reload and the browser's Back button keep it. Shared components
carry it: page header with breadcrumbs, period toolbar, theme-aware chart
with an accessible table beside it, metric cards, comparison and
availability states, attention items that each link to the one action
that fixes them. Meter detail leads with an Analysis tab and resolves its
tabs by key; the energy page has Overview, History, Flow and Meters; the
old cost-only Trends page is a general Analysis page over portfolio, type,
category, meter or a meter comparison. Records tabs are paged server-side
instead of showing the latest 200. Everything is English and German,
light and dark, down to 360px.

Some figures change on purpose; docs/RELEASE_NOTES.md lists each one and
what the first start after the update does (it rebuilds all analysis data
before the web server listens). docs/SDD.md and CLAUDE.md describe the
system as it now is.

Tests: 1,733 Core and 746 integration, all green, plus an opt-in
performance suite with a synthetic 1,000-meter generator.
2026-09-20 10:29:13 +02:00
Florian Schmidt aacdc28d70 Meters: record events from the UI, and book consumption in the months it accrued in
Two threads that ended up in the same files. One is navigation: a meter
swap that happened today had no click path at all, and most per-meter
tasks were reachable only by knowing which admin page owned them. The
other is attribution: readings on 1 August and 16 September showed six
weeks of water under September and nothing under August.

Meter events from the UI

Swap, counter reset, tank level, delivery and note are recorded through
MeterEventService rather than ad-hoc inserts, so the dialog's verdict and
the saved result come from the same Validate call, and every record or
delete recomputes the meter inside one transaction. MeterEventRules
decides which events a mode offers -- a tank has no register to swap, and
Correction is offered nowhere because nothing reads it.

A swap is stored as the event at T plus a manual reading of the new
register's start value at exactly T. That pairing is the whole trick: the
boundary window is (previousReading, reading], so the old register's tail
books at T and every later reading counts from the new start. Writing the
old final value as the reading at T instead -- the obvious thing -- double
counts the tail and then rejects every reading the new register produces.
Deleting a swap removes that start reading only while it is still the
untouched start value, and only Manual readings can be deleted at all.

Navigation

The meter page is now the hub: primary entry by mode, a "Record event"
menu, and Edit through a shared MeterEditor that also owns tank setup.
Other pages link into it with MeterLinks (/meters/{id}?tab=...&action=...),
whose action is consumed once after the interactive render and dropped
from the address -- the reverse order flashes the dialog and closes it,
because a circuit's first location change dismisses every open dialog.
The app bar gains a "Find a meter" dialog with the same quick entry.

A source that has no usable connector now links to creating (or enabling)
one and comes back to the same source dialog with the connector picked
and everything typed still there; the draft survives in a circuit-scoped
DraftStore, and the way back is a meter id rather than a URL, so the page
cannot be made to redirect anywhere else. The connector list shows which
meters use each connector, import batches list the meters and categories
they wrote to, the meter editor owns the meter's own cost categories, and
the dashboard's empty cost panel names the first missing step instead of
listing every admin page.

Months

A reading is an instant, and what it measures accrued over the time since
the previous one. Booking the whole delta at the closing reading misfiles
it whenever the interval crosses a month boundary, so a plain increase is
now divided at local month boundaries in proportion to elapsed time, each
share stamped inside its month and marked estimated: the meter recorded a
total, not a shape. The parts always sum to the original.

Imported monthly tables are the exception that keeps the golden fixtures
reconciling. "Mai 2026" carries the register at the end of May but is
stamped on the 1st, so the importer -- the only place that still knows
whether the date cell named a month or a day -- flags it MonthLabel, and
the engine reads it as the end of its month. Inferring that from the
stamp instead would catch day-dated rows: a sheet with "01.08.2026" in it
is not a monthly table, and reading it as one moves two thirds of July
into August.

ReadingTimeline is the single ordering built on that: effective time,
then stamp. The register normalizers walk it, and so do the decrease
guard and the event dialog, which is what stops them disagreeing about
which reading is "previous" -- a sheet imported after live readings of the
same month used to count that month twice, and a mid-month reading below
the month's end value was rejected as a drop. A swap detected in a
monthly table applies from the start of that local month, i.e. to the
first reading in it, and a recorded start value never counts above the
reading it lands on.

Every reader buckets in the configured timezone rather than a hardcoded
one, and turns a requested date into that zone's local midnight, so the
divided shares are read back under the months they were stamped in. The
zone id is normalised to its IANA form, because .NET accepts a Windows id
that PostgreSQL will not bucket by, and both are checked at startup.

Stored consumption is derived, so a rule change reaches a meter only at
its next reading -- weeks, for a meter read monthly. NormalizationUpgrade
records the revision and zone the stored series was built with and
rebuilds everything once at startup when either differs, each meter in
its own transaction. A meter that fails is logged, kept in
normalization_pending and retried at the next start: one bad series must
never keep the application down.

What an operator sees once

Existing charts change on the first start after the update: months that
carried a neighbour's use give it back. Rows of earlier imports from
monthly tables are marked as such before anything is recomputed, and if
that marking fails nothing is rebuilt or recorded, so the upgrade simply
runs again next time rather than shifting every imported month by one. A
wizard import whose date format was left on auto-detect is treated as a
monthly table when all of its rows sit on the 1st across at least two
months -- exactly how those rows were attributed before -- and each such
batch is named in the log, because a day-dated sheet always read on the
1st looks identical; revert and re-import it with the day format if that
is what it was.

Tests: 120 unit and 230 integration, including the reference fixtures,
which still reconcile month for month.
2026-09-17 21:09:17 +02:00
Florian Schmidt bfa0b537ee i18n: ship the UI in English and German
ci / build-test (push) Failing after 35s
The last open item on the M7 list. Number and currency formatting was
already locale-aware, but every string in the UI was an English literal,
so a German instance read half in each language -- German data, English
chrome. This translates all of it and adds the machinery to keep it
translated.

Strings live in Localization/Strings.resx (English, neutral) and
Strings.de.resx. The neutral file generates a strongly-typed accessor at
build time, aliased as S in _Imports.razor, so components reference
compiled properties -- @S.Common_Save, not a string key. That choice is
the point: across 4,500 lines of markup, a key lookup that silently
falls back to its own name is a defect you find in production, while a
renamed property is a build error. Generation runs in MSBuild rather
than the IDE designer, so dotnet build alone reproduces it anywhere.

Resource fallback is the hazard here. Ask for a key the German satellite
lacks and ResourceManager quietly serves the English one -- correct at
runtime, disastrous at release time, because a half-translated build
looks perfectly healthy. StringResourceTests reads each satellite with
tryParents: false, which is the only way to see what one actually
contains, and fails on a missing or blank translation, a placeholder
that changed arity, an orphan, or a key nothing references.

Three things needed more than substitution:

- Domain enums reached the screen as bare identifiers. They stay bare in
  the model -- they are persisted as text and appear in the REST API, so
  their names are part of the data contract -- and DisplayNames is now
  the single place that decides how each value is spoken. Every arm ends
  in a fallback returning the identifier, so a value added later cannot
  throw mid-render; EnumDisplayNameTests is what stops that safety net
  quietly becoming the shipping behaviour.

- Infrastructure was writing display text: FlowService's "Other (X)",
  MeterPeriodView's "Generation"/"Consumption", the HA connection-test
  verdicts, the updater's snackbar, the CSV importer's row warnings.
  Each now returns an outcome value and the UI supplies the words, which
  is where the reader's language is known. Diagnostics that are not ours
  -- an HTTP status, systemd's stderr, an exception message -- are passed
  through untranslated, and every English summary is kept alongside the
  outcome so log lines never move with the UI language. The UpdateRunner
  change is additive only; no gate was touched.

- Importer warnings carry their arguments rather than a finished
  sentence, so the numbers inside them pick up the reader's grouping. A
  register that reads 2.940,19 everywhere else must not read 2940.19
  only inside a warning.

Switching language is a redirect through /culture/set followed by a full
reload, not an interactive state change: a Blazor Server circuit is fixed
to the culture of the request that opened it. That makes the endpoint a
redirector taking its target from the query string, so anything but a
local path is refused rather than followed. Preference order is the
cookie, then Accept-Language, then MeterVault__Locale -- an instance can
be pinned to one language and a reader can still switch.

Locale keeps its documented default of "en". Format now follows
CurrentCulture instead of a hardcoded de-DE, so an instance with nothing
configured and a browser asking for English will show English number
formatting where it previously showed German; set MeterVault__Locale=de
to pin the old behaviour. The importer's de-DE parsing is untouched and
stays that way -- that dialect is a property of the spreadsheets, not of
whoever is looking at the dashboard.

Anything that comes from the database -- meter names, energy-type display
names, category names -- is user data and is never translated.

Claude-Session: https://claude.ai/code/session_0112ezeWqaZ85kTj5bYu9JHx
2026-08-13 16:36:25 +02:00
schmidt.florian af786c7b28 Meters: add manual reading entry from the meter-detail Readings tab
ci / build-test (push) Successful in 1m37s
Entering a reading by hand previously meant POST /api/v1/readings with an
API key, or a one-row CSV through the import wizard. SourceType.Manual
existed in the enum but nothing was behind it. This adds the click path,
built for the case it is actually used in: walking to each manual meter
with a phone in hand.

"Add reading" on the Readings tab opens a dialog prefilled with the
meter's last register value and the current local time, both editable:

- An on-screen keypad, because a register is read standing at the meter.
  It behaves like a calculator against the prefill - the first digit
  replaces it (a fresh register), while backspace edits it in place,
  which is the common case since only a register's last digits move.
- Typed input accepts both separators (last one wins), so a German and
  an English phone keyboard both do the right thing. ReadingEntry owns
  that rule and is unit-tested; it deliberately differs from
  GermanNumber, where a lone dot really is a thousands separator.
- A live parsed-value echo plus delta-since-last, which is the net that
  catches a mistyped digit before it is committed.
- Decrease / replaces-existing / future / backdated surfaced before
  saving, and DST spring-forward gaps refused rather than shifted.

The verdict line sits in a fixed-height, no-wrap slot above the keypad.
That is load-bearing, not cosmetic: an alert that appears there when the
value dips below the last reading moves the keys out from under the
user's thumb mid-entry, which is a guaranteed mistype on a phone. The
long-form explanation goes below the keypad, where reflow is harmless.

Saving goes through IngestionService.IngestByMeterAsync, so the
monotonic-decrease guard and inline renormalization apply exactly as for
any other ingest. A new optional quality parameter stamps the row
ReadingQuality.Manual; null preserves today's behaviour, so a source
re-reporting the same timestamp updates the value without silently
relabelling a hand-entered or imported reading.

Also: the meter-detail tabs now render times in the instance timezone
per SDD section 10, instead of raw UTC. Without it a reading entered at
18:00 reads back as 16:00. Side effect is that historic imported monthly
rows show 01:00/02:00 rather than 00:00 - correct, if noisier.

Claude-Session: https://claude.ai/code/session_01D4x3JbNKCSV4cBR9s7bJmX
2026-08-01 10:25:05 +02:00
schmidt.florian cf7e0396f0 Dashboard: report when a newer release is available
ci / build-test (push) Successful in 1m13s
The instance had no idea what version it was: VERSION drives tagging and the
image publish, but was never stamped into the assemblies, so a running build
reported 1.0.0 forever. Directory.Build.props now stamps it into every project.

The dashboard compares that against the newest tag in the source repository and
shows a banner when behind. A plain GET of a public tag list -- nothing about
the instance is sent -- cached six hours, failing quiet.

Two things it deliberately does not do. It never blocks a render: the banner
paints from the cached answer and refreshes after first render, so a cold start
or an unreachable repository costs nothing rather than holding the dashboard
open for an HTTP timeout. And it never guesses: an unknown version on either
side shows no banner at all, because a banner that cannot clear trains people
to ignore the next real one.

Version comparison is numeric on exactly three components, not System.Version
and not string order. Tags are written vX.Y.Z, the assembly reports X.Y.Z with
a +commithash suffix, and "0.10.0" sorts below "0.9.0" as a string -- each of
those is a way the banner sticks or never appears. Prerelease suffixes compare
equal to their release so an rc tag does not nag. Gitea does not promise semver
ordering, so the highest tag wins rather than the first.

The command shown depends on the install: the LXC has `update`, a container is
replaced by pulling an image, and telling container users to run `update` sends
them after a command that does not exist.

No update *button*. The UI has no authentication and the LXC runs the app as
root, and `update` builds whatever is on master, so a click would be an
unauthenticated path to arbitrary code execution for anything on the LAN. The
README now states the no-auth position plainly rather than leaving it implied.

Tests cover the parse and ordering cases that would strand a banner, the Gitea
payload shape captured from the live API, unreachable and garbage responses,
and that the VERSION file actually reaches the assembly -- read from MeterVault's
own assembly rather than GetEntryAssembly(), which under `dotnet test` is the
test host and reported a confident wrong answer. The suite makes no outbound
request: the app factory disables the check.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 20:17:52 +02:00
schmidt.florian 8fe5f4411b Fix defects found auditing the ingestion, import and connector changes
ci / build-test (push) Successful in 1m16s
An audit of this session's commits found several real problems, three of which
lose or expose data. Ordered by severity.

Live recompute was not atomic. RecomputeMeterAsync clears a meter's series with
ExecuteDelete, which commits by itself when no transaction is ambient, and only
then adds the rebuilt rows. Between the two the meter had *no* consumption:
a dashboard read reported zero, and a crash or cancelled request made the loss
permanent, for data the SDD treats as the long-term source of truth (§5.5).
Import and the events API already wrapped their recomputes; live ingestion,
which I added this session, did not. Now shares one transaction, joining an
ambient one rather than nesting.

The MQTT backfill migration counted brokers without regard to is_enabled. One
live broker plus a disabled leftover counted two, declined to backfill, and left
those sources unbound — which under endpoint-scoped routing means silently and
permanently dead. The "two or more is ambiguous" reasoning did not hold there:
the worker only ever connected to enabled endpoints. Corrected by a follow-up
migration rather than an edit, since the original may already have run; it
touches only rows still NULL, so hand-made bindings are safe.

A mapping edited after a dry run committed the *old* staged rows under the
*new* mapping. Readings went to the previous meter while the batch recorded the
current mapping — wrong data, provenance contradicting it, no exception. The
earlier fix re-validated but did not detect staleness. Commit now compares the
mapping against the one the preview was staged under and refuses.

"Test connection" sent a stored token to whatever Base URL was in the dialog.
Encrypting secrets at rest means the UI can decrypt what the operator can no
longer read, so this turned the button into an exfiltration primitive: point it
at any host, the token arrives as a Bearer header. A stored token now only goes
to the origin it was saved for; testing elsewhere requires typing it again.

A source that cannot ingest looked identical to a healthy one. Endpoint-scoped
routing made unbound and mis-bound sources silently dead, while the Sources tab
showed no connector at all and the delete dialog still promised sources would be
"unlinked". Added a Connector column that names the fault, stopped offering
disabled connectors (both workers filter on IsEnabled), and made the delete
warning say ingestion stops.

Virtual meters rendered four zero tiles: they evaluate on read and only
materialize when a cost category references them (§14.1), so summing
consumption is a confident lie about a working meter. They now report nothing
and the page explains why.

Re-importing an overlapping file failed at the database with EF's "An error
occurred while saving the entity changes", naming neither meter nor date — the
diagnosis problem a3af483 set out to fix, via the path its guard could not see.
Checked up front now, bounded by each meter's staged range.

The LXC updater left the service stopped on any failure. set -e plus an
explicit stop means Restart=always does not apply, so an OOM-killed publish or
a brief Gitea outage took MeterVault down until someone noticed. An EXIT trap
restarts the previous build and says so.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 19:52:48 +02:00
schmidt.florian 95c51842e8 Meter detail: lead with periods and change, not register totals
ci / build-test (push) Successful in 1m23s
The headline tiles were lifetime consumption, a raw reading count and the
register span. None of those answer why someone opens a meter: how much this
month, more or less than last, where the year lands, what it costs. A
cumulative counter's register value is an accident of when the meter was
installed.

MeterPeriodService buckets consumption by calendar month in the instance
timezone -- via date_trunc(... AT TIME ZONE) rather than EF grouping, because a
reading at 00:30 local on 1 January is 23:30 on 31 December in UTC and would be
booked to the wrong month (SDD §10). It reports generation for a generation
counter and consumption otherwise, so a PV meter stops claiming it consumed
0 kWh.

Month- and year-to-date are compared against a projection of the current period
rather than its running total. Three days into a month, "12 kWh vs 340 kWh last
month" reads as a collapse in usage when nothing has changed. The projection is
straight-line on elapsed days -- wrong for anything seasonal, but the honest
reading of "at this rate" -- and the UI marks it with a leading ~.

A 12-month bar strip gives the shape at a glance. A meter with nothing
normalized yet returns an empty history rather than a flat line, which would
look like a meter reading zero.

Register span, reading count and lifetime total move into a collapsed panel.
Still there when needed for an audit, no longer the first thing you see.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 19:10:32 +02:00
schmidt.florian 62d102c335 Ingestion: derive consumption on ingest, and poll HA in minutes not seconds
ci / build-test (push) Successful in 1m13s
Live ingestion wrote the raw reading and stopped there. Import, the REST push
endpoint and the meter editor all recompute afterwards; the MQTT/Tasmota/HA
path was the one that did not, so a polled reading landed in `reading` and
every derived figure stayed frozen at the last import. Observed on a
GenerationCounter: 45 readings, 44 consumption rows, generation pinned to the
register value of the last imported reading.

Recompute inline rather than behind a debounce. Normalizing a whole meter is
cheap at metering cadence and a background dirty-set worker is machinery this
does not yet need; the remark on RenormalizeAsync records when it would.

Fixes a latent bug this surfaced in NormalizationService: ExecuteDelete drops
the consumption rows in the database but leaves them in the change tracker, so
a second recompute on the same context threw an identity conflict on
(meter, time, kind). One worker scope ingesting two readings was enough to hit
it. Detach the stale entries after the delete.

Poll interval is now minutes, default 60, replacing seconds/60. A meter answers
"how much this month, what will it cost" — an hourly sample answers that
exactly as well as a per-second one, with far less raw volume (SDD §5.5). The
`pollSeconds` key no longer binds, so existing sources fall back to the 60
default and move from every-60-seconds to hourly, which is the intent. A source
that had deliberately set e.g. 300 seconds also lands on 60 minutes.

Two test cleanups now delete consumption before the meter: live ingestion never
produced any before, so the FK had nothing to trip on.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 18:45:57 +02:00
schmidt.florian e23df37a3f Connectors: allow secrets to be entered in the UI, encrypted at rest
ci / build-test (push) Successful in 1m12s
Reference-only secrets (SDD §6.4) meant adding a connector required editing a
file on the server and restarting the service. In practice that leads to the
token being pasted into the env-var *name* field, which fails with "environment
variable '<token>' is not set" and gives no hint what went wrong.

Add a second storage form, chosen per connector: type the secret in and it is
encrypted via ASP.NET Core data protection before it is stored. The env-var
reference stays as an equal alternative — this widens the choice rather than
replacing it. Exactly one form survives a save, so a stale secret cannot linger
and silently win; EndpointSecret.Resolve is the single resolution path.

The guarantee that matters is preserved: no plaintext in the database, so
pg_dump and JSON exports carry nothing usable. The trust boundary is stated
plainly in §6.4 — the key ring is on disk, so this protects against leaked
database content, not an attacker who already has the host, which is the same
boundary an env var has.

Details worth noting:
- Key ring defaults to /var/lib/metervault/keys, outside the app directory,
  because the LXC updater republishes /opt/metervault on every update. Docker
  gets a named volume. Overridable via MeterVault__DataProtectionKeyPath.
- Undecryptable ciphertext (key ring lost) falls back rather than throwing: an
  ingestion worker on a timer should degrade, not crash.
- The stored secret is never sent to the browser; a blank field means
  "unchanged", not "cleared".
- MQTT usernames are stored as-is — §6.4 covers tokens and passwords, and
  encrypting a username would only blank the field on every edit.
- ExportService drops *_enc values: bound to the originating key ring, so
  useless where an export would be restored. Expect to re-enter after a restore.
- HaConnectionTester now takes a resolved token, so the admin UI can test a
  token that has been typed but not yet saved.

SDD §6.4 and §9 updated to describe both forms rather than contradict the code.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 15:41:52 +02:00
schmidt.florian 9bd0d60cc8 Sources: scope the connector picker to the source type and require it
The Sources dialog listed every connector regardless of kind, so an HA source
could be bound to an MQTT broker and saved happily — then never ingest. The
picker was also clearable, and null meant opposite things per path: an HA
source with no connector is skipped outright, an MQTT one was subscribed on
every broker.

Filter candidates by the connector kind the source type needs (HA ->
HomeAssistant, MQTT/Tasmota -> MqttBroker; Tasmota has no endpoint kind of its
own), clear a selection invalidated by a type change, and preselect the sole
candidate so the single-broker case is one click. Offer a link to
/admin/connectors when none exists rather than an empty dropdown.

Save now rejects a missing or mismatched connector: such a source has no
connection details and would silently never ingest, so it should not be
possible to save it looking configured.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 11:21:21 +02:00
schmidt.florian a3af4838e8 Import: reject duplicate reading targets in the CSV wizard
ci / build-test (push) Successful in 1m15s
Mapping two Reading columns onto one meter staged two readings per row at the
same timestamp. (meter_id, time) is the reading key, so the commit failed with
a raw EF change-tracker error that named neither the column nor the meter.

- Wizard Validate() rejects duplicate Reading targets, naming the columns and
  the meter. Reading-only: Delivery/TankLevel stage events, not readings.
- CommitAsync() re-validates. Previously only Preview did, so a mapping edited
  after a dry run reached the database unchecked.
- ImportService.GuardDuplicateReadings() backstops the same case for the API
  and any other non-wizard caller, reporting meter + date.

Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
2026-07-18 09:35:36 +02:00
schmidt.florian 8550ed8d9e Ingestion: Home Assistant WebSocket push path
ci / build-test (push) Successful in 1m16s
HomeAssistantWebSocketWorker holds a persistent state_changed subscription per HA endpoint that opts in via the connector's WebSocket toggle (HaEndpointConfig.UseWebSocket): auth handshake, subscribe, ingest in real time, capped-backoff reconnect. The REST poll worker skips WS endpoints so each is served once. HaWebSocketProtocol holds the pure handshake/parse logic. Verified by 11 protocol unit tests + a live integration test against an in-process fake HA server. CLAUDE.md updated.

Claude-Session: https://claude.ai/code/session_01Kib2MniVFbD95fkgLgBBnB
2026-07-17 11:05:01 +02:00
schmidt.florian 14930bc3d8 Import: CSV mapping wizard with revertible batches
New /import/wizard: upload an arbitrary CSV, preview the column grid, map each column to a role + target meter/category + unit, dry-run, then commit as a revertible import_batch. The /import page now lists recent imports with one-click revert. Adds CsvImporter.ReadRawRows (raw preview) and Confirm.ConfirmAsync (generic confirm). Verified end-to-end in a real browser + direct DB checks.

Claude-Session: https://claude.ai/code/session_01Kib2MniVFbD95fkgLgBBnB
2026-07-17 11:05:01 +02:00
schmidt.florian b3b8b92520 Normalization: implement instant_rate mode (rate integrated over time)
The instant_rate mode existed in the enum but had no normalizer, so normalizing a power/flow sensor threw NotSupportedException. InstantRateNormalizer integrates the rate over time (trapezoidal, attributed to each interval's end reading); a per-hour rate in the meter's unit yields the consumption unit (kW->kWh, L/h->L). Registered in the engine; meter editor shows a mode hint. +4 Core tests.

Claude-Session: https://claude.ai/code/session_01Kib2MniVFbD95fkgLgBBnB
2026-07-17 11:05:01 +02:00
schmidt.florian 92438348e7 Flow: virtual "sum" meters that aggregate upstreams + demo chain
ci / build-test (push) Successful in 1m14s
Adds the "sum meter" the user asked for: a meter that doesn't physically exist
but represents the sum of other meters in the flow view.

- FlowService: a Virtual-mode meter has no readings of its own; its flow value is
  the sum of its upstream meters, resolved in topological order (so "Summe Solar"
  = Solar 1 + Solar 2, and Grid + Summe Solar → House with the remainder as
  "Other" = export / battery / inverter losses).
- Meters editor: a hint when Mode = Virtual explaining the sum-meter behaviour.
- Reference data seeds the full demo chain: Solar 1 + Solar 2 → Summe Solar;
  Netz + Summe Solar → Haus → Auto + Other — so /energy/1 shows a multi-level
  Sankey out of the box.
- Fix: SankeyChart Unit was passed as the literal string "_graph.Unit" (missing
  @) so node labels read "_graph.Unit" instead of "kWh". Caught by screenshotting
  the live page.

Test: Virtual_sum_meter_aggregates_its_upstreams. 69 Core + 50 Integration =
119 green. Live-verified with a browser screenshot of the multi-level flow.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 15:48:50 +02:00
schmidt.florian ecadbe1477 Flow: count generation meters as sources (grid + solar → house)
ci / build-test (push) Successful in 1m14s
A meter's flow value is now its throughput — consumption OR generation output —
so a generation meter (solar) acts as a source that can feed downstream meters.
Setting a load meter's upstream to {grid, solar} now splits its consumption
across both proportionally, and the remainder under the sources (grid + solar −
load) surfaces as "Other" = export + battery/inverter losses. Negative values
(savings/balance virtuals) are clamped to 0 (a ribbon can't be negative). The
per-type KPI is relabelled "Top-level throughput" since it now spans generation.

Test: Generation_meter_counts_as_source (grid 75 + solar-gen 30 → house 40 →
28.57/11.43 split, 65 remainder). 69 Core + 48 Integration = 117 green.
Live-verified: electricity flow now shows Solar 1/2 as source nodes.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 14:33:29 +02:00
schmidt.florian 85d650a8f5 Fix: enable global interactivity so dialogs/selects actually work
ci / build-test (push) Successful in 1m12s
Editing a meter (any admin dialog, select dropdown, snackbar, dark-mode toggle)
did nothing: pages declared @rendermode InteractiveServer individually, but
MainLayout — which hosts MudDialogProvider/MudPopoverProvider/MudSnackbarProvider
— was rendered by <Routes>, which was static. Inline MudDialogs and MudSelect
popovers render through those providers, so with the providers non-interactive no
dialog could ever open.

Set the render mode on <Routes> and <HeadOutlet> in App.razor (global
interactivity) and removed the now-redundant per-page @rendermode declarations
(they would otherwise throw "parent already has a render mode").

Why it slipped through: the integration render tests only issue a GET (static
prerender), which never exercises the SignalR circuit. Verified this fix with a
real headless-browser run (Playwright): the meter edit dialog opens and the
"Sub-meter of (upstream meters)" multi-select opens with options — proving the
layout providers are now interactive. 116 tests still green.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 14:22:15 +02:00
schmidt.florian 7e34aeccc8 Meter chain topology + per-energy-type flow (Sankey) pages
ci / build-test (push) Successful in 1m24s
Adds a meter hierarchy and a flow view: a downstream meter is a *subsection*
of an upstream one (not an addition), so you can see where a main meter's flow
divides — e.g. official water → garden, pool, other; grid/battery → all → car.

- MeterLink (schema + migration AddMeterLinks): a directed from→to flow edge.
  Multi-parent allowed (a merge, e.g. grid + solar → house); multi-child is a
  split. Cascade-deletes with either endpoint; unique + distinct-endpoint checks.
- FlowService: per energy type + period, builds a Sankey graph — nodes = meters
  sized by consumption; link value = downstream meter's consumption, split
  proportionally across multiple upstreams; unaccounted remainder under a meter
  becomes a synthetic "Other" node; depth via topological longest-path.
- SankeyChart.razor: hand-rolled inline-SVG Sankey (ApexCharts has no Sankey
  type) — columns by depth, nodes stacked by value, bezier ribbons sized by flow,
  left→right, theme-aware, HTML-encoded labels, tooltips. Built as a MarkupString
  to sidestep Razor's <text> element clash.
- /energy/{id} page (one per energy type): KPIs (consumption + cost), the flow
  Sankey, and the meter list. NavMenu now lists a link per energy type
  (Electricity, Water, Gas, …) loaded from the DB.
- Meters admin: cycle-safe "Sub-meter of (upstream meters)" multi-select
  (descendants excluded to prevent cycles); reconciles meter_link rows on save.
- Reference data seeds a demo chain (Haus → Auto) so electricity flow shows
  Haus dividing into Auto + Other.

Tests: FlowServiceTests (single-parent remainder; two-parent proportional
split); render test now asserts the flow chain + covers /energy/{id}. 69 Core +
47 Integration = 116 green. Live-verified: Haus 95,450 kWh → Auto 51,909 +
Other 43,541 (flow conserved), all 5 energy-type pages render.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 14:02:16 +02:00
schmidt.florian 09cd435c2b Admin write-CRUD, Home Assistant connector config, wiring audit
ci / build-test (push) Successful in 1m19s
Three requested phases.

1) Admin section (SDD §8.7) — MudBlazor inline-dialog CRUD, consistent pattern,
   delete guards, snackbar feedback, shared Confirm helper:
   - Energy types: create/edit/delete (blocks delete when meters reference it).
   - Meters: create/edit/delete; recomputes consumption when mode/baseline
     changes (NormalizationService over a fresh factory context, in a tx);
     delete cascades data (consumption+readings are Restrict → removed first).
   - A meter's ingest sources: manage on the meter-detail Sources tab
     (add/edit/delete MQTT/Tasmota/HA sources with typed config).
   - Tariffs: full CRUD (scope/component/value/validity).
   - Cost categories: CRUD + member management (meter or energy-type members).
   - Connectors: ingestion_endpoint CRUD (MQTT broker + Home Assistant);
     secrets referenced by env-var name only, never stored.
   - Settings: read-only effective-config view (settings are env-driven and
     reproducible, so an editable form would change nothing — kept honest).
   PV role is now editable on meters (MeterMeta.SetRole can clear a role).

2) Read Home Assistant — extracted a shared public HaEndpointConfig (was a
   private record in the worker), added HaConnectionTester (powers the connector
   "Test connection": checks base URL + env-resolved token, optionally reads one
   entity). Configuring an HA connector + an HA source on a meter drives the
   existing REST-poll worker end to end. (WebSocket push stays a future
   optimization; REST poll already reads HA.)

3) Wiring/placeholder audit — swept every OnClick/Href: all handlers are real,
   all internal links resolve to real routes, no TODO/stub/placeholder code.
   Fixed one genuine gap: MainLayout had no drawer toggle, so the nav was
   unreachable on narrow screens — added a hamburger button.

Tests: +6 (MeterMeta.SetRole role-removal; HaConnectionTester fail-closed
guard branches with a throwing HttpClientFactory proving no network on bad
config); render test now covers all admin routes. 69 Core + 45 Integration =
114 green. Live-verified in Docker: all admin pages 200, drawer toggle present,
Settings shows real effective config.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 11:22:17 +02:00
schmidt.florian 1282acf82c SDD §8 panels (PV/oil/meter-detail) + fix reference-data-in-Docker
Complete the SDD §8 dashboard views that were deferred at the M5 boundary,
and fix a shipping bug that left the Docker demo empty.

Bug: "Load reference data" created meters/tank/tariffs but imported zero
readings in Docker. Root cause: sampledata/ was excluded by .dockerignore and
never copied into the build stage, so the App csproj's linked Content glob
resolved to nothing at publish time; ReferenceDataImporter then silently
skipped the missing CSVs after already writing its marker meter, leaving the
DB permanently "loaded" but empty.
  - .dockerignore: stop excluding sampledata/
  - Dockerfile: COPY sampledata/ into the build stage
  - ReferenceDataImporter: fail-fast (validate CSVs exist before the marker
    meter) and throw instead of silently skipping a missing file
  - Program.cs + MeterVaultOptions: opt-in MeterVault__SeedReferenceData
    (compose METERVAULT_SEED=true) for a one-command populated demo

New SDD §8 panels (read models in Infrastructure/Dashboard, Blazor pages):
  - §8.4 Solar/PV (/solar): generation from GenerationCounter meters;
    self-consumption / autarky % / self-consumption % / savings derived from
    meters tagged total_load & grid_import via Meter.Meta role config
    (MeterRoles/MeterMeta) — nothing hardcoded by name.
  - §8.5 Oil/consumable (/consumables): tank level (cm→L calibrated), fill
    gauge, deliveries log, burner runtime, effective L/h (fixed/empirical),
    forecast-to-empty, tariff cost, monthly series.
  - §8.6 Meter detail (/meters/{id}): raw readings, normalized consumption,
    source status, tariff timeline, events, measured-vs-estimated markers.
  - Reusable SeriesChart component; nav links; Meters list rows link to detail.

Tests: MeterMetaTests (Core, +10); DashboardRenderTests extended to assert the
three panel services compute real figures and the new routes render (108 total,
all green). Live-verified in Docker: seed imports 302 readings / 347 consumption
rows; panels render (generation 16,481 kWh, oil 3,967 L) cross-checking the DB.

Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
2026-07-14 09:52:11 +02:00
schmidt.florian a6edec2b12 Polish/audit: fix bugs found by 3 subsystem audits
ci / build-test (push) Successful in 2m45s
Correctness/data:
- Fix demo cost double-count: reference importer no longer imports the Kosten Strom/Wasser
  columns for categories that are metered (only Heizung), so Wasser rollup is 70€ not 140€.
- Spurious-decrease guard: only a reset/swap in the window (prevReading, thisReading] explains
  a decrease — an old historical reset no longer permanently disables the guard.
- Gate swap auto-detection on MappingProfile.DetectCumulativeSwaps (flag was ignored).
- Prorate basePrice by bucket length (day/month/year); guard virtual expressions against NaN/Inf.

Concurrency/infra:
- Blazor: register a DbContextFactory; CostService/DashboardService and the read pages now use
  short-lived per-operation contexts (no shared circuit DbContext); guard Trends re-entrancy.
- /events: wrap event insert + consumption recompute in one transaction (atomic); 404 (not 500)
  on unknown meter.
- MQTT worker: subscribe to newly-added topics on each tick; move client cleanup into finally.
- Migrations: CREATE MATERIALIZED VIEW IF NOT EXISTS + if_not_exists on CAgg/compression/
  hypertable calls (re-run-safe after a mid-migration crash).
- HA worker: prune stale poll-schedule entries; export: null dangling ImportBatchIds on restore.

API/security:
- API fail-closed by default: with no keys and AllowAnonymousApi off, /api/v1 returns 401
  (protects /export and /import). New MeterVault:AllowAnonymousApi opt-in.
- Cap /readings batch at 5000; report ignored (unknown-meter) count; enums as strings in JSON.

+4 regression tests (guard window, API closed, /events 404, no demo double-count). 98 tests
green; Docker deploy re-verified healthy with the API fail-closed.

Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr
2026-07-13 12:56:51 +02:00
schmidt.florian d5419729e5 M5: Blazor dashboard (MudBlazor + ApexCharts)
- MudBlazor theme (dark default) + responsive drawer/appbar layout + nav.
- DashboardService read model: KPIs with period-over-period deltas, category breakdown,
  "what cost more/less" difference view, monthly trends.
- Pages: Overview (KPI cards + DeltaChip + donut + difference table), Trends (range-select
  bar chart), Meters (list + source status), Import (load reference dataset + CSV dry-run
  preview), Admin (energy types, tariffs). Charts isolated into components to avoid the
  ApexCharts/MudBlazor Color/Format name clashes.
- ReferenceDataImporter: one-click load of all four sheets as a starter dataset (meters,
  tank, tariff history, category memberships) — bundled sample CSVs copied to app output.
- End-to-end render test: import creates meters + consumption; overview/meters/trends/
  import/admin pages all return 200 with KPI cards rendered.

92 tests green (56 Core + 36 integration).

Deferred to polish: dedicated PV & oil/consumable panels, meter-detail page, full admin
CRUD, prev-year trend overlay.

Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr
2026-07-13 12:11:12 +02:00
schmidt.florian 48a7f5a825 M0: scaffold solution, EF+Timescale schema, /healthz
Five-project Clean Architecture solution (Core/Infrastructure/App + Core.Tests/
Integration.Tests) on .NET 10 with central package management, snake_case EF mapping,
and shared build/style config.

- Full domain entity set + EF DbContext for the SDD §5.3 schema (singular table names).
- InitialSchema migration (relational) + TimescaleHypertables migration (raw SQL:
  create_hypertable + compression on reading, hypertable on consumption).
- App wiring: Serilog (actually wired, unlike MQTTower), DbContext, migrate-on-startup,
  /healthz. Serves plain HTTP behind a reverse proxy (no HTTPS redirect).
- deploy/Dockerfile (2-stage, ICU-capable) + docker-compose (app + timescaledb).
- Integration.Tests: shared TimescaleFixture (Testcontainers) — migrations, hypertables,
  compression policy, and /healthz all verified green (4/4).

Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr
2026-07-13 11:02:21 +02:00