8940ef25c32a4f908ed52bee65793797589db101
4
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
8940ef25c3 |
Analysis: one selected period, one set of numbers, on every page
ci / build-test (push) Successful in 2m31s
The dashboards told several stories at once. Overview asked for full calendar years, meter detail for a fixed 12-month window that was really 13, Trends for 24 months with an Apply button, and the energy pages for 60. Each page derived "today" from UTC, so the first hours of a local day belonged to yesterday. A missing tariff, a month nobody measured and a genuine zero all rendered as 0. And a virtual meter -- the one thing the spreadsheet leans on hardest -- was excluded from analysis outright: MeterPeriodService returned null for it and the page offered a flow diagram instead. docs/DASHBOARD_ANALYSIS_CHANGE_BRIEF.md is the work order. Every choice it left open is settled in docs/ANALYSIS_IMPLEMENTATION_NOTE.md as D-01..D-58 plus amendments A-01..A-30; code, tests and release notes cite those ids. The analysis layer Core/Analysis holds the pure rules: period presets resolved once in the instance zone into a local date range and a half-open UTC range, bucket plans, calendar-unit comparisons, coverage runs with a resolution class, normalized quantities and units, the totals policy, the virtual formula parser/validator/evaluator, and the cost calculator. "Now" comes from TimeProvider; services never read the clock. Normalization now writes, in the same transaction as consumption and by diff, per-meter rollups by local day and month plus coverage runs and a rollup state (AnalysisDataWriter). AnalysisReader answers a request from those tables -- month rollups for month and year buckets, day rollups otherwise, at most two partial edge days from consumption -- and CostReader prices the result month by month. Pages, /api/v1 and the CSV export read nothing else. The unused continuous aggregates are dropped. The reader's statement count per request is constant whether it covers one meter or a thousand. On a synthetic 1,000-meter, ten-year instance the brief's target request (100 meters, ten years, monthly) takes 374 ms against a two-second target, and the Overview went from 48,244 SQL statements per load to 205. Missing is not zero Every bucket carries a status -- available, partial, missing, unresolved, invalid, pending -- derived from coverage, never from the amount, with provenance and a reason code beside it. A true zero is a number and a bar on the baseline; an unknown bucket is a gap that says why; a month whose data only exists monthly says so instead of inventing daily detail; a scope with no tariff says "not priced" instead of 0. Rows whose interval closes after now are reported separately rather than counted. Virtual meters are analysis subjects A virtual meter stores a canonical definition -- expression over m<id> references, result kind, unit and cost rule -- validated on save and on read for syntax, unknown or self references, loops and unit/kind rules. It is evaluated on read from its sources' rollups over their joint coverage: a missing source makes the bucket missing, an observed zero is a valid input, a non-finite result is invalid with its dependency path, and the page lists each source's contribution. Topology links are topology only and never rewrite a saved calculation; expression-less meters from older installs are converted once at startup. The editor has Sum, Difference and Advanced modes with a live preview. Totals and the bill Per energy type the totals policy separates use, grid import, export, generation and runtime, marks breakdown meters as breakdowns and virtual meters as views, and never adds across units. The bill follows it: grid import where there is one, separately priced subsections at their own price, feed-in only on export meters, standing charges once per scope per local day, manual costs once on their start day, categories as non-overlapping covers whose composition reconciles to the bill. The seeded demo's yearly totals now match the spreadsheet. Pages and navigation The period lives in the URL and every page reads the same contract, so a link, a reload and the browser's Back button keep it. Shared components carry it: page header with breadcrumbs, period toolbar, theme-aware chart with an accessible table beside it, metric cards, comparison and availability states, attention items that each link to the one action that fixes them. Meter detail leads with an Analysis tab and resolves its tabs by key; the energy page has Overview, History, Flow and Meters; the old cost-only Trends page is a general Analysis page over portfolio, type, category, meter or a meter comparison. Records tabs are paged server-side instead of showing the latest 200. Everything is English and German, light and dark, down to 360px. Some figures change on purpose; docs/RELEASE_NOTES.md lists each one and what the first start after the update does (it rebuilds all analysis data before the web server listens). docs/SDD.md and CLAUDE.md describe the system as it now is. Tests: 1,733 Core and 746 integration, all green, plus an opt-in performance suite with a synthetic 1,000-meter generator. |
||
|
|
92438348e7 |
Flow: virtual "sum" meters that aggregate upstreams + demo chain
ci / build-test (push) Successful in 1m14s
Adds the "sum meter" the user asked for: a meter that doesn't physically exist but represents the sum of other meters in the flow view. - FlowService: a Virtual-mode meter has no readings of its own; its flow value is the sum of its upstream meters, resolved in topological order (so "Summe Solar" = Solar 1 + Solar 2, and Grid + Summe Solar → House with the remainder as "Other" = export / battery / inverter losses). - Meters editor: a hint when Mode = Virtual explaining the sum-meter behaviour. - Reference data seeds the full demo chain: Solar 1 + Solar 2 → Summe Solar; Netz + Summe Solar → Haus → Auto + Other — so /energy/1 shows a multi-level Sankey out of the box. - Fix: SankeyChart Unit was passed as the literal string "_graph.Unit" (missing @) so node labels read "_graph.Unit" instead of "kWh". Caught by screenshotting the live page. Test: Virtual_sum_meter_aggregates_its_upstreams. 69 Core + 50 Integration = 119 green. Live-verified with a browser screenshot of the multi-level flow. Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK |
||
|
|
ecadbe1477 |
Flow: count generation meters as sources (grid + solar → house)
ci / build-test (push) Successful in 1m14s
A meter's flow value is now its throughput — consumption OR generation output —
so a generation meter (solar) acts as a source that can feed downstream meters.
Setting a load meter's upstream to {grid, solar} now splits its consumption
across both proportionally, and the remainder under the sources (grid + solar −
load) surfaces as "Other" = export + battery/inverter losses. Negative values
(savings/balance virtuals) are clamped to 0 (a ribbon can't be negative). The
per-type KPI is relabelled "Top-level throughput" since it now spans generation.
Test: Generation_meter_counts_as_source (grid 75 + solar-gen 30 → house 40 →
28.57/11.43 split, 65 remainder). 69 Core + 48 Integration = 117 green.
Live-verified: electricity flow now shows Solar 1/2 as source nodes.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
|
||
|
|
7e34aeccc8 |
Meter chain topology + per-energy-type flow (Sankey) pages
ci / build-test (push) Successful in 1m24s
Adds a meter hierarchy and a flow view: a downstream meter is a *subsection*
of an upstream one (not an addition), so you can see where a main meter's flow
divides — e.g. official water → garden, pool, other; grid/battery → all → car.
- MeterLink (schema + migration AddMeterLinks): a directed from→to flow edge.
Multi-parent allowed (a merge, e.g. grid + solar → house); multi-child is a
split. Cascade-deletes with either endpoint; unique + distinct-endpoint checks.
- FlowService: per energy type + period, builds a Sankey graph — nodes = meters
sized by consumption; link value = downstream meter's consumption, split
proportionally across multiple upstreams; unaccounted remainder under a meter
becomes a synthetic "Other" node; depth via topological longest-path.
- SankeyChart.razor: hand-rolled inline-SVG Sankey (ApexCharts has no Sankey
type) — columns by depth, nodes stacked by value, bezier ribbons sized by flow,
left→right, theme-aware, HTML-encoded labels, tooltips. Built as a MarkupString
to sidestep Razor's <text> element clash.
- /energy/{id} page (one per energy type): KPIs (consumption + cost), the flow
Sankey, and the meter list. NavMenu now lists a link per energy type
(Electricity, Water, Gas, …) loaded from the DB.
- Meters admin: cycle-safe "Sub-meter of (upstream meters)" multi-select
(descendants excluded to prevent cycles); reconciles meter_link rows on save.
- Reference data seeds a demo chain (Haus → Auto) so electricity flow shows
Haus dividing into Auto + Other.
Tests: FlowServiceTests (single-parent remainder; two-parent proportional
split); render test now asserts the flow chain + covers /energy/{id}. 69 Core +
47 Integration = 116 green. Live-verified: Haus 95,450 kWh → Auto 51,909 +
Other 43,541 (flow conserved), all 5 energy-type pages render.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
|