0319e5527fb33207199bad9a5d86e3ca7b15f67d
7
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
bfa0b537ee |
i18n: ship the UI in English and German
ci / build-test (push) Failing after 35s
The last open item on the M7 list. Number and currency formatting was already locale-aware, but every string in the UI was an English literal, so a German instance read half in each language -- German data, English chrome. This translates all of it and adds the machinery to keep it translated. Strings live in Localization/Strings.resx (English, neutral) and Strings.de.resx. The neutral file generates a strongly-typed accessor at build time, aliased as S in _Imports.razor, so components reference compiled properties -- @S.Common_Save, not a string key. That choice is the point: across 4,500 lines of markup, a key lookup that silently falls back to its own name is a defect you find in production, while a renamed property is a build error. Generation runs in MSBuild rather than the IDE designer, so dotnet build alone reproduces it anywhere. Resource fallback is the hazard here. Ask for a key the German satellite lacks and ResourceManager quietly serves the English one -- correct at runtime, disastrous at release time, because a half-translated build looks perfectly healthy. StringResourceTests reads each satellite with tryParents: false, which is the only way to see what one actually contains, and fails on a missing or blank translation, a placeholder that changed arity, an orphan, or a key nothing references. Three things needed more than substitution: - Domain enums reached the screen as bare identifiers. They stay bare in the model -- they are persisted as text and appear in the REST API, so their names are part of the data contract -- and DisplayNames is now the single place that decides how each value is spoken. Every arm ends in a fallback returning the identifier, so a value added later cannot throw mid-render; EnumDisplayNameTests is what stops that safety net quietly becoming the shipping behaviour. - Infrastructure was writing display text: FlowService's "Other (X)", MeterPeriodView's "Generation"/"Consumption", the HA connection-test verdicts, the updater's snackbar, the CSV importer's row warnings. Each now returns an outcome value and the UI supplies the words, which is where the reader's language is known. Diagnostics that are not ours -- an HTTP status, systemd's stderr, an exception message -- are passed through untranslated, and every English summary is kept alongside the outcome so log lines never move with the UI language. The UpdateRunner change is additive only; no gate was touched. - Importer warnings carry their arguments rather than a finished sentence, so the numbers inside them pick up the reader's grouping. A register that reads 2.940,19 everywhere else must not read 2940.19 only inside a warning. Switching language is a redirect through /culture/set followed by a full reload, not an interactive state change: a Blazor Server circuit is fixed to the culture of the request that opened it. That makes the endpoint a redirector taking its target from the query string, so anything but a local path is refused rather than followed. Preference order is the cookie, then Accept-Language, then MeterVault__Locale -- an instance can be pinned to one language and a reader can still switch. Locale keeps its documented default of "en". Format now follows CurrentCulture instead of a hardcoded de-DE, so an instance with nothing configured and a browser asking for English will show English number formatting where it previously showed German; set MeterVault__Locale=de to pin the old behaviour. The importer's de-DE parsing is untouched and stays that way -- that dialect is a property of the spreadsheets, not of whoever is looking at the dashboard. Anything that comes from the database -- meter names, energy-type display names, category names -- is user data and is never translated. Claude-Session: https://claude.ai/code/session_0112ezeWqaZ85kTj5bYu9JHx |
||
|
|
af786c7b28 |
Meters: add manual reading entry from the meter-detail Readings tab
ci / build-test (push) Successful in 1m37s
Entering a reading by hand previously meant POST /api/v1/readings with an API key, or a one-row CSV through the import wizard. SourceType.Manual existed in the enum but nothing was behind it. This adds the click path, built for the case it is actually used in: walking to each manual meter with a phone in hand. "Add reading" on the Readings tab opens a dialog prefilled with the meter's last register value and the current local time, both editable: - An on-screen keypad, because a register is read standing at the meter. It behaves like a calculator against the prefill - the first digit replaces it (a fresh register), while backspace edits it in place, which is the common case since only a register's last digits move. - Typed input accepts both separators (last one wins), so a German and an English phone keyboard both do the right thing. ReadingEntry owns that rule and is unit-tested; it deliberately differs from GermanNumber, where a lone dot really is a thousands separator. - A live parsed-value echo plus delta-since-last, which is the net that catches a mistyped digit before it is committed. - Decrease / replaces-existing / future / backdated surfaced before saving, and DST spring-forward gaps refused rather than shifted. The verdict line sits in a fixed-height, no-wrap slot above the keypad. That is load-bearing, not cosmetic: an alert that appears there when the value dips below the last reading moves the keys out from under the user's thumb mid-entry, which is a guaranteed mistype on a phone. The long-form explanation goes below the keypad, where reflow is harmless. Saving goes through IngestionService.IngestByMeterAsync, so the monotonic-decrease guard and inline renormalization apply exactly as for any other ingest. A new optional quality parameter stamps the row ReadingQuality.Manual; null preserves today's behaviour, so a source re-reporting the same timestamp updates the value without silently relabelling a hand-entered or imported reading. Also: the meter-detail tabs now render times in the instance timezone per SDD section 10, instead of raw UTC. Without it a reading entered at 18:00 reads back as 16:00. Side effect is that historic imported monthly rows show 01:00/02:00 rather than 00:00 - correct, if noisier. Claude-Session: https://claude.ai/code/session_01D4x3JbNKCSV4cBR9s7bJmX |
||
|
|
7e34aeccc8 |
Meter chain topology + per-energy-type flow (Sankey) pages
ci / build-test (push) Successful in 1m24s
Adds a meter hierarchy and a flow view: a downstream meter is a *subsection*
of an upstream one (not an addition), so you can see where a main meter's flow
divides — e.g. official water → garden, pool, other; grid/battery → all → car.
- MeterLink (schema + migration AddMeterLinks): a directed from→to flow edge.
Multi-parent allowed (a merge, e.g. grid + solar → house); multi-child is a
split. Cascade-deletes with either endpoint; unique + distinct-endpoint checks.
- FlowService: per energy type + period, builds a Sankey graph — nodes = meters
sized by consumption; link value = downstream meter's consumption, split
proportionally across multiple upstreams; unaccounted remainder under a meter
becomes a synthetic "Other" node; depth via topological longest-path.
- SankeyChart.razor: hand-rolled inline-SVG Sankey (ApexCharts has no Sankey
type) — columns by depth, nodes stacked by value, bezier ribbons sized by flow,
left→right, theme-aware, HTML-encoded labels, tooltips. Built as a MarkupString
to sidestep Razor's <text> element clash.
- /energy/{id} page (one per energy type): KPIs (consumption + cost), the flow
Sankey, and the meter list. NavMenu now lists a link per energy type
(Electricity, Water, Gas, …) loaded from the DB.
- Meters admin: cycle-safe "Sub-meter of (upstream meters)" multi-select
(descendants excluded to prevent cycles); reconciles meter_link rows on save.
- Reference data seeds a demo chain (Haus → Auto) so electricity flow shows
Haus dividing into Auto + Other.
Tests: FlowServiceTests (single-parent remainder; two-parent proportional
split); render test now asserts the flow chain + covers /energy/{id}. 69 Core +
47 Integration = 116 green. Live-verified: Haus 95,450 kWh → Auto 51,909 +
Other 43,541 (flow conserved), all 5 energy-type pages render.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
|
||
|
|
09cd435c2b |
Admin write-CRUD, Home Assistant connector config, wiring audit
ci / build-test (push) Successful in 1m19s
Three requested phases.
1) Admin section (SDD §8.7) — MudBlazor inline-dialog CRUD, consistent pattern,
delete guards, snackbar feedback, shared Confirm helper:
- Energy types: create/edit/delete (blocks delete when meters reference it).
- Meters: create/edit/delete; recomputes consumption when mode/baseline
changes (NormalizationService over a fresh factory context, in a tx);
delete cascades data (consumption+readings are Restrict → removed first).
- A meter's ingest sources: manage on the meter-detail Sources tab
(add/edit/delete MQTT/Tasmota/HA sources with typed config).
- Tariffs: full CRUD (scope/component/value/validity).
- Cost categories: CRUD + member management (meter or energy-type members).
- Connectors: ingestion_endpoint CRUD (MQTT broker + Home Assistant);
secrets referenced by env-var name only, never stored.
- Settings: read-only effective-config view (settings are env-driven and
reproducible, so an editable form would change nothing — kept honest).
PV role is now editable on meters (MeterMeta.SetRole can clear a role).
2) Read Home Assistant — extracted a shared public HaEndpointConfig (was a
private record in the worker), added HaConnectionTester (powers the connector
"Test connection": checks base URL + env-resolved token, optionally reads one
entity). Configuring an HA connector + an HA source on a meter drives the
existing REST-poll worker end to end. (WebSocket push stays a future
optimization; REST poll already reads HA.)
3) Wiring/placeholder audit — swept every OnClick/Href: all handlers are real,
all internal links resolve to real routes, no TODO/stub/placeholder code.
Fixed one genuine gap: MainLayout had no drawer toggle, so the nav was
unreachable on narrow screens — added a hamburger button.
Tests: +6 (MeterMeta.SetRole role-removal; HaConnectionTester fail-closed
guard branches with a throwing HttpClientFactory proving no network on bad
config); render test now covers all admin routes. 69 Core + 45 Integration =
114 green. Live-verified in Docker: all admin pages 200, drawer toggle present,
Settings shows real effective config.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
|
||
|
|
1282acf82c |
SDD §8 panels (PV/oil/meter-detail) + fix reference-data-in-Docker
Complete the SDD §8 dashboard views that were deferred at the M5 boundary,
and fix a shipping bug that left the Docker demo empty.
Bug: "Load reference data" created meters/tank/tariffs but imported zero
readings in Docker. Root cause: sampledata/ was excluded by .dockerignore and
never copied into the build stage, so the App csproj's linked Content glob
resolved to nothing at publish time; ReferenceDataImporter then silently
skipped the missing CSVs after already writing its marker meter, leaving the
DB permanently "loaded" but empty.
- .dockerignore: stop excluding sampledata/
- Dockerfile: COPY sampledata/ into the build stage
- ReferenceDataImporter: fail-fast (validate CSVs exist before the marker
meter) and throw instead of silently skipping a missing file
- Program.cs + MeterVaultOptions: opt-in MeterVault__SeedReferenceData
(compose METERVAULT_SEED=true) for a one-command populated demo
New SDD §8 panels (read models in Infrastructure/Dashboard, Blazor pages):
- §8.4 Solar/PV (/solar): generation from GenerationCounter meters;
self-consumption / autarky % / self-consumption % / savings derived from
meters tagged total_load & grid_import via Meter.Meta role config
(MeterRoles/MeterMeta) — nothing hardcoded by name.
- §8.5 Oil/consumable (/consumables): tank level (cm→L calibrated), fill
gauge, deliveries log, burner runtime, effective L/h (fixed/empirical),
forecast-to-empty, tariff cost, monthly series.
- §8.6 Meter detail (/meters/{id}): raw readings, normalized consumption,
source status, tariff timeline, events, measured-vs-estimated markers.
- Reusable SeriesChart component; nav links; Meters list rows link to detail.
Tests: MeterMetaTests (Core, +10); DashboardRenderTests extended to assert the
three panel services compute real figures and the new routes render (108 total,
all green). Live-verified in Docker: seed imports 302 readings / 347 consumption
rows; panels render (generation 16,481 kWh, oil 3,967 L) cross-checking the DB.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
|
||
|
|
a6edec2b12 |
Polish/audit: fix bugs found by 3 subsystem audits
ci / build-test (push) Successful in 2m45s
Correctness/data: - Fix demo cost double-count: reference importer no longer imports the Kosten Strom/Wasser columns for categories that are metered (only Heizung), so Wasser rollup is 70€ not 140€. - Spurious-decrease guard: only a reset/swap in the window (prevReading, thisReading] explains a decrease — an old historical reset no longer permanently disables the guard. - Gate swap auto-detection on MappingProfile.DetectCumulativeSwaps (flag was ignored). - Prorate basePrice by bucket length (day/month/year); guard virtual expressions against NaN/Inf. Concurrency/infra: - Blazor: register a DbContextFactory; CostService/DashboardService and the read pages now use short-lived per-operation contexts (no shared circuit DbContext); guard Trends re-entrancy. - /events: wrap event insert + consumption recompute in one transaction (atomic); 404 (not 500) on unknown meter. - MQTT worker: subscribe to newly-added topics on each tick; move client cleanup into finally. - Migrations: CREATE MATERIALIZED VIEW IF NOT EXISTS + if_not_exists on CAgg/compression/ hypertable calls (re-run-safe after a mid-migration crash). - HA worker: prune stale poll-schedule entries; export: null dangling ImportBatchIds on restore. API/security: - API fail-closed by default: with no keys and AllowAnonymousApi off, /api/v1 returns 401 (protects /export and /import). New MeterVault:AllowAnonymousApi opt-in. - Cap /readings batch at 5000; report ignored (unknown-meter) count; enums as strings in JSON. +4 regression tests (guard window, API closed, /events 404, no demo double-count). 98 tests green; Docker deploy re-verified healthy with the API fail-closed. Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr |
||
|
|
d5419729e5 |
M5: Blazor dashboard (MudBlazor + ApexCharts)
- MudBlazor theme (dark default) + responsive drawer/appbar layout + nav. - DashboardService read model: KPIs with period-over-period deltas, category breakdown, "what cost more/less" difference view, monthly trends. - Pages: Overview (KPI cards + DeltaChip + donut + difference table), Trends (range-select bar chart), Meters (list + source status), Import (load reference dataset + CSV dry-run preview), Admin (energy types, tariffs). Charts isolated into components to avoid the ApexCharts/MudBlazor Color/Format name clashes. - ReferenceDataImporter: one-click load of all four sheets as a starter dataset (meters, tank, tariff history, category memberships) — bundled sample CSVs copied to app output. - End-to-end render test: import creates meters + consumption; overview/meters/trends/ import/admin pages all return 200 with KPI cards rendered. 92 tests green (56 Core + 36 integration). Deferred to polish: dedicated PV & oil/consumable panels, meter-detail page, full admin CRUD, prev-year trend overlay. Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr |