app: render the panel with an injected clock so tests do not depend on the date (#12)
The headless forecast test failed from 2026-10-16 on because the panel read the real clock while its fixture fixes the time. - App: PanelWindow takes an optional TimeProvider (the system clock by default) and passes it to the pace bar, burn-up, peak and usage charts and every forecast label. The burn-up chart uses the panel's render time as now. - Tests: headless panels run on a fixed clock at fixture time, with a check before, at and after the forecast start. App and Core tests with fixed-date Claude events pin HistoryStore's clock, so the 60-day retention cannot drop them later. Closes #11
This commit was merged in pull request #12.
This commit is contained in:
@@ -156,7 +156,7 @@ public sealed class LimitAnalysisTests
|
||||
[Fact] public void ModelSeriesGroupsInOnePassAndMatchesTotals()
|
||||
{
|
||||
using var directory = new TestDirectory();
|
||||
var store = new HistoryStore(directory.Path, new DiagnosticLog());
|
||||
var store = new HistoryStore(directory.Path, new DiagnosticLog(), new TestClock());
|
||||
store.Add(new(Provider.Claude, Now.AddHours(-2), "a", "p", new(Total: 20), "a"));
|
||||
store.Add(new(Provider.Claude, Now.AddHours(-2), "b", "p", new(Total: 30), "b"));
|
||||
store.Add(new(Provider.Claude, Now.AddHours(-1), "a", "p", new(Total: 40), "c"));
|
||||
|
||||